metal roof panel manufacturers NFPA 70E And Its Impact On Thermographers

by:Carlos     2019-04-05
There is still a lot of activity in terms of the NFPA 70E update scheduled for release on October 2008.For version 2008 of the NFPA 70,National Electrical Code®(NEC®),Technical Committee (TCC)received 3,668 recommendation and 3,206 comments during the revision cycle.For those of us who are involved in the work of the power-on circuit, the results of the new standard may affect the way we work.The goal is to improve safety through practice and through careful consideration.How does the thermostat solve this problem?Increase the distance to check the open cabinets.Most cameras offer telephoto lenses that make the thermostat stand 2 to 3 times further away from vibrant components while maintaining the same resolution.In addition, the new HD camera will provide the same performance as the 320x240 array of cameras in double normal confrontation.ASTM E-The new language is being proposed in the next version of astm e-1934,Standard for inspection of distribution equipment with infrared technology.7.5 -As an alternative,It can be considered that the "window" is checked, which is transparent to the detected infrared radiation or "port.Security procedures should be modified to accommodate this task.Care must be taken to ensure that all devices are visible and special lenses may be required.Did You Know?The arc flash incident energy created from the vertical,Unterminated conductor in cabinet (20 "x 20"Reduced from the reciprocal of the distance to 1.5 power.If the arc has a horizontal conductor, indicate that the cabinet opening or vertical termination to the insulation barrier,Exposure could reduce a lower index,But there is not enough data collected on these conductor configurations.-The following new languages have been submitted,And is considering,By the 70E Committee:"In carrying out this kind of inspection on the power-on device, proper use of special windows or small power-on ports is limited,Instead of getting access by opening the enclosure door,The limit of the method,And required PPE,Will be the same if the shell door is not open.Although it is only referenced in Part 1910 of the OSHA 29 CFR,Appendix A,NFPA 70E is recognized by OSHA as an industry practice for electrical safety.The OSHA standard does not provide detailed information on how to conduct an electrical hazard assessment or how to select a PPE.Guidance on compliance,You need to look for national consensus criteria.NFPA is one of the primary consensus criteria for electrical safety.It covers the protection of employees from electric shocks,Flash of arc and explosion of arc.Part I -Covers the safety requirements for the design and installation of wires and equipment.The key to the proper use of the first part of this standard is to understand that it is not intended to be applied as a design,installation,modification,Or construction standards for electrical installations or systems.Compared to NEC's content, its content is deliberately restricted in order to be applied to electrical installations or systems as part of the employee's workplace.This standard complies with the corresponding provisions of NEC,But not,nor can it,Used in place of NEC.Part 2 -Covers work practices and procedures related to electrical safety for employees who work or are close to exposed electrical conductors or circuit components.Electrical hazards include arc flashes.Relevant requirements include:Covering actual security-Relevant maintenance requirements for electrical equipment and devices in the workplace.Part 4 -Covering electrical safety installation requirements and safety-Relevant work practices and procedures of employees engaged in special electrical equipment such as electrolytic cells.Step 1.Label is the first step.However,Determine the arc-The flash level may change as daily maintenance and repairs are carried out.Level of arc-The flash hazard of any device depends on the level of the arc-Fault current and the time of tripping the nearest upstream current protection device.In most cases,The local utility engineer can determine the fault current level;However, these fault current values may be based on the impedance of the transformer serving the equipment,And additional impedance upstream Transformers can reduce the number.If these additional impedance are not included in the calculation,Then the energy level of the event may be lower-estimated.Short-With the replacement of over-current equipment by electricians and maintenance personnel, the circuit current level in the power system is constantly changing,Fuse and panel or upgrade system.Any of these changes can have an impact on the arc-Flash energy levels,But not on the warning label.Step 2.The next step is to ensure that anyone working on a device that may generate an arc flash wears protective clothing,Including flame retardant suit,gloves,Standard provided by face shield/goggles and other gears.Step 3.Although no single piece of equipment can completely eliminate the harm of arc flash,Easily perform most of the day-to-day maintenance tasks without direct access to the device can significantly reduce risk.External plug-in provided-The equipment inside the shell is a method.Properly designed and insulated panels connected to the appropriate equipment allow operators to change settings and monitor performance without opening the enclosure.There is a traditional disconnect switch inside the main housing,Real-time power supply still exists on the line side of the disconnect switch.Since the field power supply is still delivered upstream of the disconnect switch on the panel,The threat of the arc flash event remains.Another way is to develop arc-The electrical cabinet design contains arc energy and direct distance from personnel--They can't prevent the arc from flashing."Arc-"Resistance", describes the device to control arc flash exposure by extinguishing the arcBy controlling the propagation of the arc or by guiding the arc pressure wave away from the personnel.Arc-Resistance design represents enhanced safety technology,therefore,Improve the level of safety."Designed to redirect the arc flash energy release vents at the top of the unit and away from the personnel through an overhead plenary session.These products have been successfully tested according to ANSI c37.20.7:Ie guide for test media-Voltage Metal-Arc failure inside the closed switch.During the test,Cotton Square (similar to 4.5 oz/yard untreated T-Shirt material)Install 1 m from MCC.The acceptance criteria require that no cotton indicator be ignited during or after the test.Redirect Arc exhaust,Special silicone coating,The aluminum pressure relief vent opens the release pressure on the roof of the unit.The air-tight system above the housing transports over-heated gas and vaporized copper and steel to a safe and controlled position.To protect operatorsThe OSHA and NFPA 70E standards require "flash protection boundaries ".OSHA adopts the National Fire Protection Association's workplace electrical safety 70E standard as an acceptable means of compliance that meets this requirement.Section 1910.The sub-section of 333 states:"Safety-Relevant work practices should be adopted to prevent electric shock or other injury caused by direct or indirect electrical contact ".Therefore, the company should take great efforts to ensure that electrical workers are safe arc-flash dangers.References:NFPA -The mission of the international non-profit organization NFPA is to reduce the burden of fire and other hazards worldwide on the quality of life by providing and advocating consensus norms and standards,research,training,and education.The total number of members of the NFPA exceeds 81,000 people from all over the world and from trade and professional organizations in more than 80 countries.Established in 1896,NFPA is the world's leading fire advocate and an authoritative source of public safety.In fact,300 regulations and standards of the NFPA affect each buildingprocess,service,design,And installed in the United States,And many used in other countries.NFPA focuses on the code of the Association for real consensus help-The development process was certified by the National Standards Association of the United States (ANSI).OSHA -OSHA's mission is to send every worker home every day, healthy.Since the establishment of the agency in 1971,The number of deaths in the workplace decreased by 62%, and the incidence of occupational injuries and diseases decreased by 40%.At the same time,U.S.Employment has almost doubled from 56 million workers in 3.5 million locations to 0.115 billion workers were in nearly 7 million locations.ASTM International (Originally known as the American Association for Testing and MaterialsOne of the largest voluntary standards development organizations in the world-Reliable sources of material technical standards,products,systems,and services.Known for its high-tech quality and market relevance,ASTM International standards play an important role in guiding the design of information infrastructure,Manufacturing and trade in the global economy.IEEE -Main areas of standard activities within Ie-SA addresses the technical and related security needs of power and energy industry and subsequent industry applications.A key component of electrical safety is the standards and regulations that work with current and use current in the environment, including safety best practices.Employees must be familiar with these documents and the organization responsible for developing them.The IEEE,That is, through its color book standards for industrial and commercial power systems and national electrical safety regulations,And its standards for power engineering,Is a major standard developer that directly or indirectly addresses electrical safety in a specific application or environment.
Custom message
Chat Online 编辑模式下无法使用
Chat Online inputting...