aluminum panels Collapsed Glass in Thermopane Windows

by:Carlos     2019-04-08
Glass or double paneled windows are made up of two glass plates,Separated and sealed together with a spacer strip.Some windows are injected with argon into the cavity between glass panels to improve energy efficiency.Argon is due to its high insulation mass ratio to ambient air.In some cases, argon disappears from the mouth of the window, resulting in a partial negative pressure or vacuum in the mouth of the window.There are other possible reasons for the collapse of the glass window.In the manufacturing process of large thermoelectric piles,One glass panel is placed on the other,Separated by intervals,Then sealed together.The top panel of the larger thermal assembly will naturally bend down the center due to its weight,Because it is sealed to the heat.The result is that the pressure or gas inside the window cavity is small,This may cause the collapse of the glass condition after it is installed and cooled.Ideally,After the manufacture of large units,It will be placed upright and briefly ventilated to allow the cavity to be balanced with the breathing tube and the resealed.The unbalanced large thermal paraffin will have a lower pressure in the window cavity after it stands up.Some smaller hot glass units are made of single-strength glass (1/16").This glass can.Because of its weakness,Bending inward in extreme cold conditions,Reduce the insulation quality of windows.In a cold climate, the pressure reduction in the glass cavity is an important issue,Because of the gas (air)There is a partial vacuum in the mouth of a collapsed window (low pressure)Which contract,And bend the two panels of the glass inward.Signs of falling glass are a faint rainbow colored spot in the center of the window (This is where the glass panel touches.,In some cases, an oval or circular condensation point is at home in the center of the window.Homeowners may think that because the oval condensation point disappears at a warm temperature,The problem may have been solved.This is not the case.This condition may recur and the loss of heat through the glass will recover.A windows R-The value is mainly determined by the amount of space in the window cavity.When the space between the glass is reduced,Insulation quality (R-value)Reduction of thermal components.The collapsed glass bends the two panels of the glass,Reduce the space in the window cavity,Thus the insulation quality of the window is reduced.This extremely curved glass plate also causes premature sealing failure,This will require a hot pentane replacement.In some cases, the glass can be forced to bend together and one or two panels will be crushed.The collapsed glass can be repaired.Using specialized tools, technicians can penetrate the glass,So as to alleviate the negative pressure and balance the window cavity with the external environment.A clear seal and then place it in the hole again-Sealed windows.This will restore the insulation quality of the window minus the original argon.If the collapsed glass occurs in the tempered glass window (Tempering is required for patio doors or other large units)The glass cannot be drilled because it can be drilled in the annealing unit (Conventional heat).These tempered glass units can be removed from the window frame, allowing the program to be completed by penetrating the seal and the interval,Allow the Environment Air balance window mouth,and then re-Sealing unit.Collapsed glass is becoming a problem more and more because the age of the window and the original argon dissipated from the mouth of the window.As energy prices rise,It is more important than ever to restore the insulation properties of the windows and save the glass from future replacement.
Custom message
Chat Online 编辑模式下无法使用
Chat Online inputting...